船用通信信號RS-485W網絡電纜
1. 產品說明
光伏發電用 RS-485W是從RS-232、RS-422通訊協議電纜演變提升而來,可替代RS-232、RS-422類型產品,是產品性能出眾的一種產品。
船用通信信號RS-485W網絡電纜可用于各種復雜的工業自動化控制網絡通訊,可采用二線與四線方式。二線制可實現真正的多點雙向通信。
2. 產品型號及名稱
3. 產品參數
型號規格
|
結構(㎜)
|
電纜外徑(㎜)
|
特性阻抗(Ω)
|
RS-485W
|
2*24AWG(12/0.15)
|
7.7
|
120±10
|
2*18AWG(16/0.254)
|
8.2
|
RS-485W(23)
|
2*18AWG(1/1.01)
|
12.3
|
船用通信信號RS-485W網絡電纜4. 產品性能
具有較強的抗干擾性能,可應用于各種復雜的工業自動化控制網絡通訊。
用于多點互聯時非常方便,可省掉許多信號線,可支持32個驅動器和32個接收器。
具有超長的傳輸距離,在19kpbs下能創術1200米,如采用增加中繼的方法對信號進行放大,*多可加入8個中繼,
可傳輸距離達9600米。
特性阻抗為120歐姆,電纜附有獨立的TC接地導線,是傳輸RS-485、RS-232、RS-422通訊協議的專用電纜。
敷設條件,可根據環境要求,-40℃~90℃
允許*小彎曲半徑>10D
鎧裝雙屏蔽型電纜,可用于鼠害嚴重以及有防雷防爆要求的場所,彎曲半徑>15D
RS-485W NET CABLES
1. Product Description
RS-485W are developed and upgraded from RS-232、RS-422 communication protocol cables. They have outstanding products
properties and can replace RS-232、RS-422 type products. They can be used in all kinds of complicated industrial automation
control network communication. They can
be in the two lines and four lines way. It will achieve really multipoint two-way communication if they are
in the two lines way.
2. Model and Name
Model
|
Name
|
RS-485W(23)
|
Communication net cables (armored)
|
船用通信信號RS-485W網絡電纜
3. Technical data
Model specifications
|
Structure(㎜)
|
Outside diameter of cable(㎜)
|
Characteristic impedance(Ω)
|
RS-485W
|
2*24AWG(12/0.15)
|
7.7
|
120±10
|
2*18AWG(16/0.254)
|
8.2
|
RS-485W(23)
|
2*18AWG(1/1.01)
|
12.3
|
4. Product features
Having good anti-jamming performance, they can be used in all kinds of complicated industrial
automation control network
communication.
It is very convenient to be used in multiple spot connections.船用通信信號RS-485W網絡電纜 They can support 32 drivers and 32 receivers.
They have overlong transmission range. They can transfer signals 1200 meters. If you magnify signals by using
relay, you can add 8 relays at most and the transmission range can be 9600 meters.
Characteristic impedance is 120 Ohm. Cables have independent TC earth conductor in add. They are special
purpose cables for transmission of RS-485、RS-232、RS-422 communication protocol.
About laying condition, they can meet the environmental requirement : -40℃~90℃
Minimum bending radius >10D
Armored double screened cables can be used in seriously jamming, frequently rodent places and sites where the
lightning protection and anti-explosion needs have. Minimum bending radius>15D
船用通信信號RS-485W網絡電纜